CO2-PCL0A NDIR Module
User Manual
Product Description
PCL0A is a general infrared CO2 sensor module formed using the NDIR infrared absorption detection principle.
Performance Characteristics
Output Mode |
UART, PWM |
No. of Channel |
Single |
Dimension |
33 mm x 12 mm x 10 mm |
Applicaiton |
Fresh Air Fan, Air Detector |
Environmental
Storage Temperature |
-40℃ ~ 70℃ |
Working Temperature |
-10℃ ~ 60℃ |
Working Humidity |
0% ~ 95%RH non-condensing |
Technical Data
Description |
Parameter |
Unit |
Detection Range |
0 ~ 5,000 (customizable) |
ppm |
Detection Accuracy |
±50 ppm ± 5% reading (customizable) |
/ |
Response Time (T90) |
< 2 |
minutes |
Warm-Up Time |
Start to Work < 30 |
seconds |
Precision Reached < 5 |
minutes |
Working Voltage |
5 ± 0.5 |
V |
Working Current |
Iavg: 75 |
mA |
Ipeak: 140 |
mA |