This infrared sensor functions based on the NDIR principle for monitoring carbon dioxide (CO2) presence. It features a highly accurate optical system equipped with a durable light source and a temperature-compensated infrared detector with dual channels. The electronic circuit includes a microprocessor with embedded intelligent software, which handles signal acquisition, processing, and output. Furthermore, it simultaneously performs environmental temperature compensation, rectifies response non-linearity, and offers multiple output options.
Output Mode | UART |
Analog (0.4 ~ 2.0 V) | |
Number of Channel: | Dual |
Dimension | Industrial standard 4-series |
Storage Temperature | -40℃ ~ 70℃ |
Working Temperature | -40℃ ~ 70℃ |
Working Humidity | 0% ~ 95%RH non-condensing |
Expected Operating Life | 6 years in clean air |
Warranty | 24 months |
Detection Range | 0 ~ 5,000 (customizable) ppm |
Detection Accuracy | ±(50 ppm + 5% of reading) |
Response Time (T90) | < 30s @ 20°C ambient |
Warm-Up Time | Start to work < 30s @ 20°C ambient |
Precision reached < 5min @ 20°C ambient | |
Working Voltage | 3.0 ~ 5.5 VDC |
Working Current | Iavg: 45 / Ipeak: 74 mA |
Resolution | 1% of measuring range |
Zero Repeatability | ±500 ppm @ 20°C ambient |
Span Repeatability | ±500 ppm @ 20°C ambient |
Long Term Zero Drift | ±500 ppm / month @ 20°C ambient |
Telephone: +1-(510)-766-9639
Website: www.semeatech.com
Email: info_us@semeatech.com